RADCLAMPS Environmentally friendly

 saves water

 reduces chemical additives

 discharged to sewerage

 system

Radclamps in Use - no need to drain

Radclamps

 in use

 retains water

 no need to drain

 Saves time & money

Radwrench in use. Safely undo seized union nuts

Radwrench

 in use

 safely undo stubborn

 union nuts

 Saves time & money

TapSplitter in use. Safely undo seized headgear nuts

TAPSPLITTER Environmentally friendly

stop drips & save water

 undo seized headgear nuts

 no risk to sinks, baths, basins or pipe joints

» Home   » Track Order   » Contact Us   » Help & Support
Search Products:  
Central Heating Radiator Tools & Kits
Easy Tapsplitter & Pozibite
Spares & Supplies
Central Heating Pump Tools
Olive Pullers / Olive Extractors

Warranty
Radkit User Guide
TapKit User Guide
PoziBite User Guide
Customer's Feedback
Track Order
About Us
Contact Us
Favourite Links
Help & Support

Google Checkout
PayPal

 

 

Comment 01 October 2010 21:53

 

Hi,

My Radclamp set arrived today and the radiator was off in about 5 mins

no mess, brilliant.

Does exactly what it says...

Worth every penny.

Regards

Graham W

Comment 13 January 2011 17:32

Just wanted to give you a huge thank you for your fantastic Tapsplitter. It made easy and fast work of removing two formerly impossible-to-remove headgear nuts. I’m very impressed... and very grateful.  Many thanks.

Anne N


PoziBite User Guide

ABD TOOLS

ABD PoziBite User Instructions

The PoziBite is used with an ABD Tools  TapSplitter, so many of the instructions follow the TapSplitter guide. The additional PoziBite instructions are underlined.

NOTE: the PoziBite is for DAMAGED NUTS ONLY. A metal point is screwed into the nut to grip securely, which will damage the nut.

Before starting work, make sure the plug is in the plughole. This stops anything falling down the plughole. Identify a safe place to store components as they are removed.

  1. Turn off water supply to the tap and open the tap to drain off water in pipes.

  2. Remove the tap handle cap (usually marked hot or cold) to get to the tap handle fixing screw. Safely store the cap.

    1. Some caps require levering out.

    2. Other caps require unscrewing.

  3. Remove the tap handle fixing screw and the tap handle. Safely store the screw and handle.

  4. Remove the tap bonnet (if fitted) from over the tap headgear nut. Safely store the bonnet.

    1. We recommend using a rubber strap wrench to prevent damage to the tap finish.

  5. The tap headgear nut must be unscrewed in an anticlockwise direction access the tap washer.

  6. Select the PoziBite insert and screw the cap screw into place 

  7. Put the small toothed 'dog bit', teeth facing inward, into the the cut out in the PoziBite and place the PoziBite over the tap head nut.

  8. Use a hexagon key to screw the cap screw tightly into the tap head nut, forcing the pointed cap screw at least 1.5mm into the brass nut. Pre-drilling in the correct position with the correct angle will help secure the nut, but is not essential.

  9. Place splitter spanner over the insert to the left of the tap at approx 45 degrees to the spout.

  10. Place the TapTool sleeve over the spout with the slot to the right hand side of the tap.

  11. If the TapTool sleeve is loose remove it, insert wide rubber filler and replace. If still loose, add smaller rubber insert and replace.

  12. Place the washer on the eyebolt and screw the long nut onto the end of the eyebolt.

  13. Attach eye of the eyebolt over the end of the spanner and place the nut & washer in the sleeve slot; you are now ready to undo the headgear.

  14. Hold the tap splitter components steady with one hand, and use the small spanner to screw the long nut clockwise against the sleeve.

  15. The tap spanner is pulled in the direction of the spout and will “crack “ the joint. Keep turning the small spanner to free the head nut further, allowing it to be unscrewed later with ease. 

  16. The force applied is indirect and guaranteed not to damage ceramics or water pipes however much is applied when following these instructions.

  17. Use a hexagon key to remove the cap screw and replace PoziBite in the case.

  18. Replace the tap washer and tap head nut.

  19. The TapTool can be used to tighten up the tap head by placing the components on the other (right hand) side of the tap, again with no danger of damage to ceramics or water pipes. Use the normal inserts, not the PoziBite insert.

  20. Reassemble the tap in reverse order and turn the water back on.

Done - it's as easy as ABD!

 

Shopping cart is empty.

View Shopping Cart

Click below to watch us now on the BBC's

DRAGON'S DEN

Please contact us if you require any further information on any of our products. Trade enquiries welcome.

Sales Agents required all areas


Home | Contact Us | Help & Support | Terms & Conditions | Privacy Policy | Sitemap
Copyright © 2012 Advanced Building Design. All rights reserved.
Powered by Store2Go E-commerce Store Builder.